Test Standards: AAMA, ASTM, WDMA


AAMA/WDMA/CSA  101/I.S.2/A440-05: Standard/Specification for windows, doors, and unit skylights.

AAMA-103 (Section 5): Procedural guide for certification of window and door assemblies (Section 5: Auxiliary Test Procedures).

AAMA-501.2: Quality assurance and diagnostic water leakage field check of installed storefronts, curtainwalls, and sloped glazing systems.

AAMA-906: Voluntary test method and specification for sliding glass door roller assemblies.

AAMA-920:  Specification for operating cycle performance of side-hinged exterior door systems .

AAMA-925: Specifications for determining the vertical loading resistance of side-hinged door leaves.

AAMA-1304: Forced entry resistance test method for sliding glass doors.

ASTM E283: Determining rate of air leakage through exterior windows, curtain walls, and doors under specified pressure differences across the specimen.

ASTM E330: Structural performance of exterior windows, doors, skylights, and curtain walls by uniform static air pressure difference.

ASTM E331: Water penetration of exterior windows, doors, skylights, and curtain walls by uniform static air pressure difference.

ASTM E547: Water penetration of exterior windows, doors, skylights, and curtain walls by cyclic static air pressure difference.

ASTM E783: Field measurement of air leakage through installed exterior windows and doors.

ASTM E987: Standard test method for deglazing force of fenestration products.

ASTM E1105: Field determination of water penetration of installed exterior windows and doors.

ASTM E2068: Determination of operating force of sliding windows and doors.

ASTM F588: Measuring the forced entry resistance of window assemblies, excluding glazing impact.

ASTM F842: Measuring the forced entry resistance of sliding glass door assemblies, excluding glazing impact.

WDMA TM 7-08 (Cycle-Slam Test): Test method for determining the physical endurance of wood doors & associated hardware connections under accelerated operating conditions. 
 
 